Popular Searches

  • Slip ring motor for a cement mill in Belgium
    Slip ring motor for a cement mill in Belgium

    6600 V Slip ring (IC 611 + IC 616 + IC 666) Mill drives Slip ring motor for a cement mill in Belgium Customer: Belgian Grinding Plant (Belgium) Menzel got the contract, for an already three times failed motor, to manufacture an identical reserve The new 6600 V motor was produced interchangeable, that the customer could even use the original .

    Know More
  • Motor Sizing Calculations - Oriental Motor USA Corp
    Motor Sizing Calculations - Oriental Motor USA Corp

    Motor Sizing Calculations There are three factors to calculate when sizing a motor; Moment of Inertia, Torque, and Speed Moment of Inertia Moment of inertia is the measure of an object's resistance to changes in its rotation rate When an object is just sitting without any motion, the moment of inertia is 0

    Know More
  • Engineering tools: LOCKED ROTOR CURRENT OF A MOTOR
    Engineering tools: LOCKED ROTOR CURRENT OF A MOTOR

    May 22, 2012· The magnitude of the Locked rotor current is determined by motor horsepower and design characteristics Normally it will be 6 to 7 times of the Motor full Load current Normally Motor Name plate contains KVA code or Design Letter We can calculate the Locked Rotor Current Using the following Formula Single Phase = (577 x HP x KVA/HP)/V

    Know More
  • Electrical Motors - Full Load Amps
    Electrical Motors - Full Load Amps

    Note that most electric motors are designed to run at 50% to 100% of rated load and that maximum efficiency usually is near 75% of rated load For a 1 horsepower (hp) motor the load should typically be in the range 1/2 to 1 hp with maximum efficiency at 3/4 hp Typical load ranges: acceptable for a short-period: 20 - 120%

    Know More
  • Calculating Mill Drive RPMs: Is Your Mill Up to Speed?
    Calculating Mill Drive RPMs: Is Your Mill Up to Speed?

    Calculating Mill Drive RPMs: Is Your Mill Up to Speed? By Robert A Sladky Vice President Tube Mill Engineering Many "W" style mills that have the ability to shim up the bottom driven shafts in each section to maintain metal line after tooling is reworked, and are many times also equipped with a individual motor drive in each of the three sections as illustrated below

    Know More
  • CARBON BRUSHES FOR MOTORS AND GENERATORS
    CARBON BRUSHES FOR MOTORS AND GENERATORS

    l For electrical machines under heavy vibration (eg traction motors): 350 - 500 g/cm2 (500 - 711 psi) Equal spring pressure must be maintained for all carbon brushes to ensure a good current distribution We therefore advise periodic pressure measurement with a scale or a load cell BRUSH-HOlDERS

    Know More
  • Motor Data - Three-Phase AC Motors - Wire Size Calculator
    Motor Data - Three-Phase AC Motors - Wire Size Calculator

    A heater is a device that protects a motor from thermal overloads due to excess current in the windings According to the NEC, the overload rating must not exceed 115% of the full-load current of the motor For example, the full-load current of a 10 HP motor at 230V is 28 Amps Therefore, the heater must be sized for 28 * 115 = 322 Amps

    Know More
  • 3 Phase Motor Current Calculation Formula Explained ,
    3 Phase Motor Current Calculation Formula Explained ,

    Feb 03, 2018· For three phase motor amps calculation, the below formula is used 3 phase motor current calculation formula is P/ (√3xVxPfxEff) or P/ (1732xVxPfxEff) Both are the same So our motor power is 15KW with 15 x 1000 = 15000 Watts Motor volts are 380 volts, Eff is 089 and PF is 085 according to the above nameplate

    Know More
  • Motor loads calculation - Electrical Engineering Centre
    Motor loads calculation - Electrical Engineering Centre

    Jul 24, 2012· Electrical motor loads are calculated from power in kW and full rated load in kWFollowing is the formula how to calculate Motor loads Example : We have 1 unit Induction Motor with 30 horsepower (hp),running with 349 amps for amperage load and 460 volts 3 phase and power factor value is 075 and motor efficiency is 85%

    Know More
  • Gear Units - Calculation and Selection
    Gear Units - Calculation and Selection

    Gear Units - Calculation and Selection ν t b 108 027 F u d 2000 3000 325 n 1 n 2 Result: Gear 58_5_09 Page GB-6 only Travelling Operation 108 6366π T 2Table K A S b B T 2erf n 2 9550 η 132 324 9550 090 ν t b F u d 2000 ν d π n 1 n 2 T 2Table K A S b B T 2erf n 2 9550 η Your Calculation Values .

    Know More
  • How to Read a Portland Cement Mill Test Report
    How to Read a Portland Cement Mill Test Report

    the characteristics of all concrete components Mill Test Reports Mill Test Report Chemical Physical Optional Bogue Nomenclature • C = CaO • S = SiO 2, • A = Al 2 O 3 • F = Fe 2 O 3 Example C 3 A = 3CaOAl 2 O 3 Chemical Requirements , • The standard Bogue calculation refers to cement

    Know More
  • ABB knows the most common bearing diffi culties and how ,
    ABB knows the most common bearing diffi culties and how ,

    Motor coupled to the load Warning >7 mm/sec Motor coupled to the load Trip >9 mm/sec Rule of thumb for vibration protection settings Support class Validation RMS velocity (mm/sec) Rigid A/B B/C C/D 23 45 71 Flexible A/B B/C C/D 35 71 110 Validation A: Newly commissioned motors should be in this range Validation B: Acceptable for long .

    Know More
  • Calculation methods – conveyor belts
    Calculation methods – conveyor belts

    Calculation methods – conveyor belts Content 1 Terminology 2 Unit goods conveying systems 3 , determined from the installed motor power P M as per the given formula and used to select a belt type , Cement 15 – 20 Goods Bulk density ρ[103kg/m3] Gypsum, broken 135 05 – 06

    Know More
  • Ball Mill Motor Power Draw Sizing and Design Formula
    Ball Mill Motor Power Draw Sizing and Design Formula

    Oct 19, 2015· Ball Mill Motor Power Draw Sizing and Design Formula The following equation is used to determine the power that wet grinding overflow ball mills should draw For mills larger than 33 meters (10 feet) diameter inside liners, the top size of the balls used affects the power drawn by the mill This is called the ball size factor S

    Know More
  • How to calculate cement ball mill capacity - Quora
    How to calculate cement ball mill capacity - Quora

    You can ask your vendor who made this machine It’s difficulty to calculate capacity of a machine or maximum capacity It’s depend on a lot of parameters But you .

    Know More
  • iampsr: CALCULATION TABLE FOR SLIP RING INDUCTION MOTOR ,
    iampsr: CALCULATION TABLE FOR SLIP RING INDUCTION MOTOR ,

    Feb 23, 2014· With P =T * w that calculation for torque above where it is given as: Torque (FL) T = 4274713376 Nm is way too high for a 75kW(100HP) motor Perhaps recheck that calculation, Also Peak Torque (TStm) dived by Full load torque (Tm) is way too high This is not what you get in real life, That is, calcs are out, Reply Delete

    Know More
  • PROCESS DIAGNOSTIC STUDIES FOR CEMENT MILL ,
    PROCESS DIAGNOSTIC STUDIES FOR CEMENT MILL ,

    A 15 mio t/a cement plant is having a closed circuit ball mill for cement grinding: The mill has been operating with satisfactory performance in-terms of system availability and output, however power consumption was on higher side 31 System Description Mill Rated capacity 150 t/h OPC at ,

    Know More
  • The basics of motor testing
    The basics of motor testing

    Jul 06, 2016· Using proprietary algorithms, the 438-II from Fluke measures the three-phase current and voltage waveforms and compares them against rated specifications to calculate motor mechanical performance It provides analysis data for both the electrical and mechanical characteristics of the motor while in operation

    Know More
  • Calculations | Simple Electric Motors
    Calculations | Simple Electric Motors

    The motors have enough torque and speed to do all kinds of experiments and calculations Measuring the torque of the motor is a challenging task It requires special expensive equipment Therefore we suggest calculating it Efficiency of the motor is calculated as mechanical output power divided by electrical input power: E = P out / P in .

    Know More
  • Ball Mill Design/Power Calculation
    Ball Mill Design/Power Calculation

    Jun 19, 2015· Example Calculation A motor with around 1400 Horse Power is calculated needed for the designed task Now we much select a Ball Mill that will draw this power The ball mill motor power requirement calculated above as 1400 HP is the power that must be applied at the mill drive in order to grind the tonnage of feed from one size distribution The following shows how the size or select the .

    Know More
  • Cement Formulae - Green Business Centre
    Cement Formulae - Green Business Centre

    Calculations III Flame Momentum Calculation 16 IV Kiln Performance & Efficiency 17 V Heat Transfer 19 VI Economic Insulation Thickness 21 VII Physical Chemistry 25 VIII Useful Formulae in Kiln Design & 26 Operation IX Grinding Mill Investigation 28 X Tromp Curve Calculation and 31 Significance XI Electrical Engineering 34 XII Fan Engineering 35

    Know More
  • Batch Plant and Central Mixer Operations Manual
    Batch Plant and Central Mixer Operations Manual

    CON-E-CO 237 N 13th Street Blair, NE 68008 4024264181 FOR PARTS CALL 1-800-656-2651 OR con-e-co ®CON-E-CO, the CON-E-CO logo and other designated trademarks.

    Know More
  • Code Calculations | EC&M
    Code Calculations | EC&M

    Mar 01, 2001· In this installment, we'll take a look at how to calculate motor and noncoincident loads Motor loads (Secs 430-24, 430-25, and 430-26) When calculating motor loads, you need to know how to convert a motor's current rating (given in amps) to a VA rating To do this, multiply the motor's nameplate amperage by the supply voltage

    Know More
  • Generator Sizing Calculation Guide - Grainger KnowHow
    Generator Sizing Calculation Guide - Grainger KnowHow

    Jan 15, 2017· The next item to look at for generator sizing is the volt-amperes (wattage) requirement of electric motor to be operated (eg, furnace blower motor 1/3 HP), remembering that the starting requires 2 to 3* times the nameplate or running (rated) watts Thus, if running watts of the motor is 600, multiply the number by 3 to determine approximate max

    Know More
  • SAGMILLINGCOM : Mill Critical Speed Determination
    SAGMILLINGCOM : Mill Critical Speed Determination

    The "Critical Speed" for a grinding mill is defined as the rotational speed where centrifugal forces equal gravitational forces at the mill shell's inside surface This is the rotational speed where balls will not fall away from the mill's shell Result #1: This mill would need to spin at RPM to be at 100% critical speed Result #2: This mill's .

    Know More
  • How to Calculate Property Tax Using Mill Rate | Finance ,
    How to Calculate Property Tax Using Mill Rate | Finance ,

    Oct 31, 2018· So to convert millage rates to dollar rate amounts, divide each mill rate by 1,000 Continuing with the example, divide 10 mills by 1,000 to get ,

    Know More
  • VRM and ball mill circulating load - Page 1 of 1
    VRM and ball mill circulating load - Page 1 of 1

    Sep 07, 2011· Re: VRM and ball mill circulating load Mainly in USA , the term circulating load is more often used than the circulation factorCirculating load is percentage of coarse return in relation to fines & it can be calculated by : Coarse return TPH X 100 / Mill output TPHNormal range of cirulating load in a conventional close circuit ball mill is around 100-200%

    Know More
  • Macfarlane Generators Power Calculator
    Macfarlane Generators Power Calculator

    Generator Size to Start Motors Instructions: Fill in the HP of the motor (s) in their starting sequence, select the start method (DOL - Direct On Line or Star Delta) and press Calculate The required generator size will then be displayed at the bottom 3 Phase (415 volt @ 50Hz) 1 Phase (240 volt @ 50Hz) Starting Sequence Motor HP Start Method

    Know More
  • Roller Drive Chain Selection and Engineering Information
    Roller Drive Chain Selection and Engineering Information

    232 renoldjeffrey • advancing chain technology 29 Roller Drive Chain Selection Technical Information Step 5: Select the Number of Teeth on the small sprocket The minimum number of teeth are found in the horsepower tables on pages 6-19 To determine, first calculate the Horsepower Table Rating (HP Table) from the following

    Know More
  • Motor Sizing Made Easy | Machine Design
    Motor Sizing Made Easy | Machine Design

    Mar 02, 2011· For example, calculations calling for a 66-oz-in motor might result in using the next size up, a 100-oz-in motor, to provide a 17 safety factor Common safety factors are in the 15 to 20 range

    Know More